Connecting with Eight or Less Servers

Connect the cables to the server switch unit in the following procedure. (The figure below shows an
example of the server switch unit installed in the rack with eight servers connected.)

1. Connect the keyboard/mouse connector and display connector of the first server through the

dedicated cable (K410-118 or K410-119). First connect the cable to the connector on the
server switch unit. (Connect in the order of

 and ‚.)

Tips

It is recommended to attach the Device ID Label to the cable with destination
device name filled in. It is useful when relocating or cleaning the unit.

Use the dedicated cables listed below to connect the server switch unit with the server.

Name Part

Number

Remarks

Server switch unit USB
connection cable set (1.8
m)

K410-118(1A)

Used to connect the server to the server
switch unit via USB connection.

Server switch unit USB
connection cable set (3.0
m)

K410-118(03)

Used to connect the server to the server
switch unit via USB connection.

Server switch unit USB
connection cable set (5.0
m)

K410-118(05)

Used to connect the server to the server
switch unit via USB connection.

Server switch unit PS/2
connection cable set (1.8
m)

K410-119(1A)

Used to connect the server to the server
switch unit via PS/2 connection. Always
use this cable between master and slave
sides in cascade connection.

Server switch unit PS/2
connection cable set (3.0
m)

K410-119(03)

Used to connect the server to the server
switch unit via PS/2 connection.

Server switch unit PS/2
connection cable set (5.0
m)

K410-119(05)

Used to connect the server to the server
switch unit via PS/2 connection.

-

50

-