Setting the retrigger mode – Roland Audio Processor SL-20 User Manual

Page 19

Advertising
background image

19

Operating the SL-20

Setting the Retrigger Mode

The Retrigger Mode setting determines whether or not the slice pattern will be cued to
the beginning when the START/STOP pedal is pressed during reception of MIDI Clock.

1.

While holding down the PEDAL MODE button, turn on the power to the SL-20.

The upper part of the TEMPO indicator lights in green.

* Plugging into the INPUT R/MONO jack switches on the power.

2.

When the TEMPO indicator starts flashing, release the PEDAL MODE button.

3.

Use the PATTERN knob to set the retrigger mode.

4.

Press the PEDAL MODE button.

The TEMPO indicator flashes three times, and the setting is saved to the SL-20’s
internal memory.

Once the setting is saved, and the SL-20 returns to its normal operating status.

* Be sure not to turn off the power while the TEMPO indicator is flashing.

* This setting remains stored even after the power is turned off.

* With the factory default settings, Retrigger Mode is set to Off.

PATTERN

Retrigger Mode

Explanation

5

Off

The slice pattern won’t be cued to the beginning
when the START/STOP pedal is pressed.

6

On

Pressing the START/STOP pedal cues the slice
pattern to the beginning.

SL-20_e.book 19 ページ 2008年3月28日 金曜日 午前8時28分