FOR YOUR SAFETY READ BEFORE OPERATING

1. TURN OFF ALL ELECTRIC POWER TO THE

APPLIANCE IF SERVICE IS TO BE PERFORMED.
2. SET THE THERMOSTA T TO LOWEST SETTING.

TO TURN OFF GAS TO APPLIANCE

OPERATING INSTRUCTIONS

B. BEFORE OPERATING smell all around the

appliance area for gas. Be sure to smell next to

the floor because some gas is heavier than air

and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance

• Do not touch any electric switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's

instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to turn the gas control knob.

Never use tools. If the knob will not turn by hand,

don't try to repair it, call a qualified service

technician. Force or attempted repair may result

in a fire or explosion.
D. Do not use this appliance if any part has been

under water. Immediately call a qualified ser -

vice technician to inspect the appliance and to

replace any part of the control system and any

gas control which has been under water.

WARNING

: If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

3. TURN THE "GAS CONTROL KNOB" CLOCK-
WISE TO "OFF" .

8. TURN ON ALL ELECTRIC POWER TO THE

APPLIANCE.

9. SET THERMOSTAT TO D ESIRED SETTING.
INSTAL L OUTER COVER.

STOP! READ THE SAFETY INFORMATION

ABOVE ON THIS LABEL.

1.

TURN OFF ALL ELECTRIC POWER TO TH E

APPLIANCE.
THIS APPLIANCE IS EQUIPPED WITH AN

IGNITION DEVICE WHICH AUTOMATICALLY

LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE

PILOT BY HAND.

TURN THE "GAS CONTROL KNOB" CLOCK-

WISE

TO " OFF".

5.

WAIT FIVE (5) MINUTES TO CLEAR OUT ANY

GAS. IF YOU THEN SMELL GAS, STOP! FOL-

LOW "B" IN THE SAFETY INFORMATION

ABOVE ON THIS LABEL. IF YOU DON'T SMEL L

GAS,

6.

GO TO NEXT STEP.

TURN THE "GAS CONTROL KNOB" COUNTER-

CLOCKWISE TO "ON".

7.

IF THE APPLIANCE WILL NOT OPERATE, FOL-

LOW THE INSTRUCTIONS "TO TURN OFF GAS

TO APPLIANCE" AND CALL YOUR SERVICE

TECHNICIAN

10.

OR GAS SUPPLIER.

REMOVE OUTER COVER. USING A SLOTTED

SCREWDRIVER - INSERT INTO SLOT IN CENTER

OF DIAL. TURN DIAL COUNTERCLOCKWISE

TO THE LOWEST SETTING .

2.

TEMPERATURE

ADJUSTMENT

DIAL

NOTE: Thermostat

shown with cover

removed .

THERMOST AT

A. This appliance is equipped with an ignition

device which automatically lights the pilot. DO

NOT try to light the pilot by hand.

4.

3.

Index

Ga s C ock
Knob

Honeywell

GAS VA LV E

Operation

1. LIGHTING PROCEDURE - Lighting procedures are outlined on the label pictured below. This label is also located on the water heater near the thermostat.

NOTICE: The Gas Valve supplied with this water heater may vary from the one pictured on the label below, but the Lighting Instructions are the same for all

types of valves supplied with this model water heater.

Before operating this water heater, be sure to read and follow the instructions on the label pictured below and all other labels on the water

heater, as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in prop-

erty damage, bodily injury, or death. Should you have any problems reading or following the instructions in this manual, STOP, and get

help from a qualified person.