System sentinel” troubleshooting guide – Rheem Commercial Power Direct Vent Water heater User Manual

Page 21

Advertising
background image

21

Section 2... the “ThERmOSTAT” lED

“System Sentinel” Troubleshooting guide

is Thermostat set at a tempera-

ture higher than the water tem-

perature in tank?

Thermostat is

defective or out of calibration

and must be replaced.

Adjust

Thermostat to a higher setting.

is Thermostat lED now illumi-

nated?

Thermostat is calling for

heat, and 24 VAC power.

YES

YES

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO

CAUTION

!

label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERiFY PROP-

ER OPERATiON AFTER SERViCiNg!

Ensure that power is being supplied to

the water heater. Refer to “Section 1...the

POWER lED” in this Troubleshooting guide,

and correct if necessary. is the “ThERmO-

STAT lED” now illuminated.

Ensure that power is being supplied to

the water heater. Refer to “Section 1...the

POWER lED” in this Troubleshooting guide,

and correct if necessary. is the “ThERmO-

STAT lED” now illuminated.

is 24 VAC

power present at Yellow Wire

Terminal inside Thermostat?

is 24 VAC power present at

Blue Wire Terminal inside Ther-

mostat?

is the “ThERmOSTAT” lED illuminated?