Acceleration

Address:

^03

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the rate at which the controller internally changes the command
value from the one it was to the one just received.

Input Switches Function

Address:

^04

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter enables and configures the effect of the controller’s Digital Inputs and other
settings.

Bit

Definition

See pages

7:0

0 = very slow

1 = slow

(2) = medium-slow (default)

3 = medium

4 = fast

5 = fastest

See “Programmable Acceleration”
on page 40 f
or complete list of
acceptable values

Bit

Definition

See pages

1:0

Enable and
Configure
Invert/Estop

(00) = Input Disabled (default)

01 = Input as Emergency Stop

10 = Disabled

11 = Input as Invert Command

page 45

page 45

2

Output C when
Motor On

(0) = No Action (default)

1 = Output C On when either motor is On

page 45

3

Encoder Safety

Unavailable