Rc joystick or analog deadband, Exponentiation on channel 1 and channel 2 – RoboteQ Dual Channel Digital Motor Controller AX500 User Manual

Page 117

Advertising
background image

AX500 Motor Controller User’s Manual

117

Accessing & Changing Configuration Parameter in Flash

RC Joystick or Analog Deadband

Address:

^06

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the amount of joystick or potentiometer motion can take place
around the center position without power being applied to the motors.

Exponentiation on Channel 1 and Channel 2

Address:

^08 - Channel 1
^09 - Channel 2

Access:

Read/Write

Effective:

Instantly

5:4

Input E

Unavailable when Encoder Module is
present

(00) = No action (default)

01 = Cut FET power when Input E is Low

10 = Activate output C

11 = Cut FET when Input E is High

page 46

page 46

7:6

Input F

(00) = No action (default)

01 = Cut FET power when Input E is Low

10 = Activate output C

11 = Cut FET when Input E is High

page 46

page 46

Bit

Definition

See pages

7:0

Values are for Joystick deadband

0 = no deadband

1 = 8%

(2) = 16% (default)

3 = 24%

4 = 32%

5 = 40%

6 = 46%

7 = 54%

page 88

or

page 97

Bit

Definition

See pages

Advertising