Serial (RS-232) Controls and Operation

122

AX500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

The Controller Status Register can be polled at any time to see if there is a pending fault
condition. Any one bit set will cause the controller to turn off the Power Output stage. Con-
ditions marked as Temporary mean that the controller will resume operation as soon as the
fault condition disappears. Permanent conditions will cause the controller to remain off
until it is reset either by cycling power, pressing the reset button, or sending the %rrrrrr
command.

Controller Identification Register

Address:

^8A

Access:

Read Only

Effective:

Instantly

This register may be used to query the Controller’s model and some of its optional hard-
ware configurations.

Current Amps Limit Registers

Address:

^8B - Channel 1
^8C - Channel 2

Access:

Read Only

Effective:

Instantly

TABLE 21. Controller Status Register Definition

Bit

Fault Condition

Effect

0

Overvoltage

Temporary

1

Overtemperature

Temporary

2

Undervoltage

Temporary

3

Manually Forced MOSFETs Off

Temporary

4

Unused

5

Confirmed Short Circuit

Permanent

6

Confirmed Encoder Error

Permanent

7

Emergency Stop Pressed

Permanent

TABLE 22. Controller Identification Register Definition

Bit

Model or Function

0

AX500

1

AX1500

2

AX2500

3

AX3500

4

Unused

5

Encoder Present

6

Short Circuit Detection Present

7

Unused