Serial (RS-232) Controls and Operation

120

AX500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

The table below lists the available parameters

Important Notice:

Do not write in the locations marked as Read Only. Doing so my cause Controller
malfunction.

Operating Modes Registers

Address:

^80 - Channel 1
^81 - Channel 2

Access:

Read/Write

Effective:

Instantly

Modifying the bits in the Operating Mode registers will change the controller’s operating
modes on-the fly. Changes take effect at the controller’s next 16ms iteration loop. After
reset, these bits get initialized according to the configuration contained in Flash.

Values are in Hexadecimal.Example: 00000101 = Hex 05

TABLE 19. Runtime R/W Parameters list

Location

Function

R/W

^80

Channel 1 Operating Modes

R/W

^81

Channel 2 Operating Modes

R/W

^82

PID Proportional gain 1

R/W

^83

PID Proportional gain 2

R/W

^84

PID Integral gain 1

R/W

^85

PID Integral gain 2

R/W

^86

PID Differential gain 1

R/W

^87

PID Differential gain 2

R/W

^88

PWM frequency

R/W

^89

Controller Status

R Only

^8A

Controller Model

R Only

^8B

Current Amps limit 1

R Only

^8C

Current Amps limit 2

R Only

TABLE 20. Operating Modes Register Definition

Bit

Function

7 to 3

Not Used

2

0: Open Loop

1: Closed Loop

(when in Speed Mode)