Chapter 2 Installation and Setup

ASM-20 Installation and Operation Manual

2-6

Connecting the Cables

Table 2-3. Async Character Length Setting

Start Bit

Data Bits Parity

Stop Bit

No. of Bits

1 5 NONE 2

8

1

6

NONE

1, 1.5, 2

8
9

1

6

ODD, EVEN

1, 1.5, 2

9

10

1

7

NONE

1, 1.5, 2

9

10

1

7

ODD, EVEN

1, 1.5, 2

10
11

1

8

NONE

1, 1.5, 2

10
11

1

8

ODD, EVEN

1, 1.5, 2

11

2.6

Connecting the Cables

The line and digital interface connectors (located on the rear panel of ASM-20)
consist of a DTE interface connector and a five-screw terminal block. The DTE
interface connector may be 34-pin for V.35 (see

Figure 2-2

), 15-pin for X.21 (see

Figure 2-3

) or 25-pin for RS-530/RS-422 or RS-232/V.24.

The terminal block provides a connection between transmit and receive twisted
pair lines. The transmit and receive pairs are polarity insensitive. The transmit pair
is connected to the terminals marked XMT, the receive pair is connected to the
terminals marked RCV. If the cable is shielded, the shield may be connected to the
terminal marked GND.

CAUTION:

FOR CONTINUED

PROTECTION AGAINST RISK OF
FIRE, REPLACE ONLY WITH SAME
TYPE AND RATING OF FUSE.

DTE

XMT

RCV

GND

Figure 2-2. ASM-20 - V.35 Rear Panel

~

230 V

A

C

-1A

T

250V

DTE

X.21

Line Connector

CAUTION:

FOR CONTINUED

PROTECTION AGAINST RISK OF
FIRE, REPLACE ONLY WITH SAME

TYPE AND RATING OF FUSE.

Figure 2-3. ASM-20 - X.21 Rear Panel