ASM-20 Installation and Operation Manual

Chapter 4 Troubleshooting and Diagnostics

Communication Link Tests

4-5

RCVR

RCVR

LOCAL
DATA
TERMINAL

XMTR

XMTR

LOCAL ASM-20

REMOTE ASM-20

DATA

DATA

CLK

CLK

REMOTE
DATA
TERMINAL

REM
Pressed

Figure 4-4. Remote ASM-20 in Digital Loopback

Local Digital Loopback

This test is activated by pressing the DIG push button. It loops the received data
back to the remote ASM-20. (This test is equivalent to activating the remote
loopback from the remote ASM-20 – see

Figure 4-5

). The operator at the remote

end can determine the performance of the local and remote ASM-20 units, and
the lines between them.

The modem with the pressed DIG push button must be in RCV or ASY mode

RCVR

RCVR

DIG
Pressed

LOCAL
DATA
TERMINAL

XMTR

XMTR

LOCAL ASM-20

REMOTE ASM-20

DATA

DATA

CLK

CLK

REMOTE
DATA
TERMINAL

Figure 4-5. Local ASM-20 in Digital Loopback

Note