Pin assignment, Ir-x.21b interface module, C.3 ir-x.21b interface module – RAD Data comm ASM-20 User Manual

Page 60

Advertising
background image

Appendix C IR-X.21B Interface Module

ASM-20 Installation and Operation Manual

C-2

IR-X.21B Interface Module

The ASM-20 modem rack version requires an additional adapter to connect
between the DB-15 connector of the X.21 equipment to the DB-25 connector of
the ASM-MN-214 modem rack. For this purpose, an optional DB-15 attachment
CIA/X.21 can be ordered separately from RAD. The attachment connects to the
ASM-MN-214 rear panel as shown in

Figure 5-3

for the CIA/V.35 attachment.

Pin Assignment

Table C-1

shows the X.21 DB-15 pin assignment.

Table C-1 IR-X.21B DB-15 (RS-422) Connector Pin Assignment

Pin ID

Function

1 Shield

Chassis

connection

2

A

Transmit signal A

3 A Control

A

4 A Receive

A

5 A Indication

A

6 A Signal

timing

A

7 A External

Timing

8 GND

Common

9

B

Transmit B

10 B

Control

B

11 B

Receive

B

12 B

Indication

B

13

B

Signal Timing B

14 B

External

Timing

C.3 IR-X.21B

Interface

Module

The IR-X.21B interface module is shown in

Figure C-3

. It has two operation modes

which are selectable on the PCB board. The selection is made by means of the JP2
jumper located within the module as shown in the figure. The EXT mode is

described on

page C-3

and illustrated in

Figure C-4

. The INT/RCV mode is

described on

page C-4

and illustrated in

Figure C-5

.

The X.21 interface should be in accordance with the modem clock mode. For
example, if the modem is in the EXT mode, then JP2 should be set to the EXT
position.

Note