E-1

Appendix E
Connection to RS-422

Table E-1

describes how to connect ASM-20 (EIA 530) to a RS-422 (V.36) DTE.

Table E-1. Interface List for Connecting ASM-20 (RS- 530) to RS-422 (V.36) DTE

Signal Function

RS-449 (RS-422/423)

37 Pins

EIA 530

DB-25 Female Standalone and Frame

Pin

Circuit

Pin

Circuit

Protective Ground

1

Shield

1

Signal Ground

19

SG

7

AB

DTE Common Return

37

SC

DCE Common Return

20

RC

Transmitted Data

4

SD (A)

22 SD

(B)

2 BA

(A)

14 BA

(B)

Received Data

6

RD (A)

24 RD

(B)

3 BB

(A)

16 BB

(B)

Request to Send

7

RS (A)

25 RS

(B)

4 CA

(A)

19 CA

(B)

Clear to Send

9

CS (A)

27 CS

(B)

5 CB

(A)

13 CB

(B)

Data Set Ready

11

DM (A)

29 DM

(B)

6 CC

(A)

22 CC

(B)

Data Terminal Ready

12

TR (A)

30 TR

(B)

20 CD

(A)

23 CD

(A)

Carrier Detect

13

RR (A)

31 RR

(B)

8 CF

(A)

10 CF

(B)

External Transmit Clock

17

TT (A)

35 TT

(B)

24 DA

(A)

11 DA

(B)

Transmit Clock

5

ST (A)

23 ST

(B)

15 DB

(A)

12 DB

(B)

Receive Clock

8

RT (A)

26 RT

(B)

17 DD

(A)

9 DD

(B)

Local Analog Loopback

10

LL

18

LL

Remote Loopback

14

RL

21

RL

Test Indicator

18

TM

25

TM