Lan installation, Switch settings, Led indicators – RAD Data comm ASM-20 User Manual

Page 52: Figure a-6

Advertising
background image

Appendix A Ethernet Interface

ASM-20 Installation and Operation Manual

A-4

Installation and Operation

1

2

3

4

Figure A-6 Ethernet Bridge Layout (BNC option)

LAN Installation

For 10BaseT installation, either a straight cable or a cross-cable may be required.
Use a cross-cable when connecting to a port that does not implement the
crossover function internally. Otherwise, use a straight cable. (Hubs usually
implement the crossover function internally while NICs and other devices do not.)

Switch Settings

Set switches according to Table A-2.

Table A-2 DIP Switches Settings

Switch
Number

Name Description*

1

SQ/FD

ON:

Ethernet full-duplex mode

OFF

: Ethernet half-duplex mode

2 CMP

ON

: Strips padding bits inserted in 64-byte frame

OFF: Transmits frames over WAN as is

3 FIL

ON

: Passes only frames destined for another LAN

OFF: Disables LAN filter; passes all frames transparently

4

(nc)

* Default settings are shown in bold.

The SQ/FD switch is not used in the Ethernet bridge with the BNC connector
option.

LED Indicators

Table A-3

lists the IR-ETH LED indicators and describes their functions.

Note