Prepare the Up-N-Down Transfer kit
The next step is the preparation of the Up-N-Down Transfer kit,

if you have not already done so:
1. With the 5 gallon Up-N-Down container in the vertical position,

unscrew the plastic vent cap in the handle and pierce the

plastic membrane over the vent boss under the cap to allow

the container to vent.
note: If your container does not have the vent cap and vent

boss, drill a 3/16” hole in the handle. When you have finished

deliming you will be able to plug this drilled vent with the

stainless steel screw that is supplied with the kit.

2. remove the container’s cap and cut the plastic membrane

located in the 3/4” IPT opening in the cap. Take care to not

damage the threads.

3. Find the 3/4” male adapter, apply teflon tape to the threaded

end and screw it into the 3/4” IPT opening in the cap.

4. Put cap with male adapter back on the container and slide

3/4” hose over end of male adapter and fasten in place using

hose clamp provided.

Delime using Flo-Jug method
5. Slide the hose clamp over end of hose and slide hose over the

male adapter in the water heater drain opening and secure in

place using hose clamp.

6. Lift container to the “Pour” Position, see Figure 28, being

careful to keep the vent in the handle above the liquid level

and pour the UN•LIme into the heater.

7. Lower container, you may have to place the container on its

empty carton to prevent the UN•LIme from flowing back into

the container.

8. Let UN•LIme remain in the heater for 5 minutes and then

lower the container to the “Drain” Position, see Figure 28.

9. Deliming activity is indicated by foaming on the surface of the

UN•LIme. If there is deliming activity, repeat steps 6 thru 8.

Normally, lime removal will be completed within one hour.

Severe build-up of lime may take longer than an hour to complete

descaling.
Note: To check UN•LIme for continued use, place some scale

or white chalk in a glass with a small amount of UN•LIme. If

the material is vigorously dissolved by the UN•LIme, it can be

reused; if not, the UN•LIme should be replaced.

figure 28.

Chemical Hazard

• Product contains phosphoric acid.
• Keep out of reach of children.
• Use rubber or neoprene gloves.

UN•LIme contains phosphoric acid. In case of external contact,

flush with cool water. If irritation persists, get medical attention. If

swallowed, give 1 or 2 glasses of water or milk and call physician.
Get immediate medical attention for contact with eyes. keep out

of reach of children.
note: the use of rubber or neoprene gloVes is

recommended, especially if you haVe any open

sores or cuts to aVoid unnecessary irritation

or discomfort.
1. Turn off fuel and/or power supply to heater. Also, turn off power

to any electrical device or equipment, which is attached, or

part of the system.

2. Open hot water side of faucet closest to heater and allow

water to run until it is cool enough to handle safely.

3. Close cold water inlet valve to heater.
4. Connect hose to drain valve at bottom of heater and start

draining heater into suitable floor drain area.

5. remove relief valve while heater is draining. NOTe: Do not

replace relief valve until deliming is completed. relief valve

opening will also act as a vent in case of possible contact

between the delimer and the anode rod(s), which may

produce flammable hydrogen-air mixtures.

6. If relief valve appears to be limed-up, place it in a clean glass or

plastic container adequate in size so that you can pour enough

UN•LIme® into the container to cover the valve and allow

space for foaming. When foaming stops, run fresh cool water

into the container and rinse the relief valve for a few minutes.

7. If heater does not drain completely after a reasonable length

of time, turn off the main water supply valve to stop water from

entering the tank due to a by-pass problem or defective cold

water inlet valve. Also, check for clogged drain valve opening.

heater must be completely drained before introducing UN•LIme.

8. remove the cleanout cover and place a clean plastic bucket

next to the cleanout opening.
Partially open the cold water inlet valve to allow time to

accomplish the following and then close the valve.
While the water is being run through the tank, insert a stiff

wire, copper tube flattened at one end or an opened wire coat

hanger through the cleanout opening and scrape out any

loose deposits of scale or sediment. This is an economical

way to avoid unnecessary usage of the deliming solution.
repeat the opening and closing of the cold water inlet valve

as necessary but be sure the heater is completely drained

when ready to introduce the UN•LIme.
Upon completion, reinstall the cleanout cover and use a new

cleanout cover gasket (part number 9004099215).
remove the drain valve.

9. Install the long plastic male adapter insert fitting into the drain

valve opening of heater after applying Teflon tape or paste to

threads. Tighten firmly by hand and use wrench or adjustable

pliers to check for secure connection. Do not over tighten to

avoid damage to threads and fittings.