Installation considerations, Rough in dimensions, Recovery capacities – Reliance Water Heaters D85500PE User Manual

Page 8: Gas and electrical characteristics, Top view

Advertising
background image

8

top View

f

top

outlet

1 1/2” npt

top

inlet

1 1/2” npt

figure 5

rough in dimensions

recoVery capacities
gas and electrical characteristics

front View

back View

TABLE 2. RECOVERY CAPACITIES, based on 80% efficiency

table 3. gas and electrical characteristics

table 1. rough-in-dimensions

model

Input Rate

Btu/Hr

kw/hr

Approximate

Tank Cap

G/L

Dimensions in Inches/cm

Connections

Approx. Ship Weight

Inlet (NPT)

Outlet (NPT)

A

B

C

D

E

F

Gas

Inlet

G

H

Vent

Dia

I

J

Top

Front Back

Top

Front Back

Std.

Lbs/

kgs.

ASme

Lbs/

kgs.

D85500NE/

D85500PE

500,000

85

81.50 17.50 77.25 67.50 27.13 21.00 1.00 67.50 8.00 27.75 1.50

1.50

1.50

1.50

1.50

1.50

812

857

D85500NE/

D85500PE

147

322

207

44

196

171

69

53

3

171

20

70

1.50

1.50

1.50

1.50

1.50

1.50

368

389

model

Input Rate

Btu/Hr

kw/hr

Approximate

Tank Cap

G/L

recovery rating Capacities (GPh and LPh) at temperature rise indicated

30°F

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

140°F

17°C

22°C

28°C

33°C

39°C

44°C

50°C

56°C

61°C

67°C

72°C

78°C

D85500NE/

D85500PE

500,000

85

1616

1212

970

808

693

606

539

485

441

404

373

346

D85500NE/

D85500PE

147

322

6118

4588

3671

3059

2622

2294

2039

1835

1668

1529

1412

1311

model

Gas Type

Gas Supply Pressure

Gas manifold Pressure

Volts / hz

Amperes

Minumum

Maximum

D85500NE/

D85500PE

Natural

4.5" W.C. (1.12 kPa)

14" W.C. (3.48 kPa)

3.5" W.C. (0.87 kPa)

120/60

<5

D85500NE/

D85500PE

Propane

11" W.C. (2.74 kPa)

14" W.C. (3.48 kPa)

10" W.C. (2.49 kPa)

120/60

<5

installation considerations

Advertising