Ignition module system, System diagnostics, Service – Reliance Water Heaters D85500PE User Manual

Page 30: Electrical servicing, For your information, Start up conditions, Operational conditions, Ignition module system system diagnostics, Start up conditions operational conditions, For your information service

Advertising
background image

30

system diagnostics

your water heater is equipped with an ignition module that

incorporates a diagnostic system to assist in troubleshooting the

appliance. The indicator codes on the ignition module are as follows:

table 11:

1 FLASh

System lockout (retries or cycles exceeded)

2 FLASheS

Pressure switch stuck close

3 FLASheS

Pressure switch stuck open

4 FLASheS

Open on high temperature limit switch (eco)

6 FLASheS

115 volt AC power reversed (check polarity)

7 FLASheS

Low flame sense signal (make sure flame sensor is in

burner flame)

8 FLASheS

Check ignitor

continuous flash -> continuous flame sensed > 5 seconds without

gas valve
continuous on -> internal control failure - replace ignition control

module.
Use this diagnostic system in conjunction with the “OPerATIONAL

CheCkLIST” and the “SeQUeNCe OF OPerATION” to

troubleshoot the appliance.

ignition module system

Before calling your service agent, the following checklist should

be examined to eliminate obvious problems from those requiring

replacement or servicing.

• Check that “main manual gas shutoff valve” is fully open and

that gas service has not been interrupted.

• Check that after following the appliance OPerATING

INSTrUCTIONS, the “Top knob” of the appliance gas valve

is in “ON” position.

• Check electrical supply to the appliance for possible blown

(or tripped) fusing or power interruption. Also check the 3

amp fuse on the front of the digital thermostat (Fig. 2).

• Is the water temperature in tank below the thermostat dial

setting on the appliance thermostat (calling for heat)?

• It is possible that the high limit (e.C.O.) has functioned to

shut off the appliance. See high Limit page 7 - high Limit

Switch for reset procedure. Contact your service agent if limit

continues to function to shut off appliance.

for your information

serVice

The installer may be able to observe and correct certain problems

which may arise when the unit is put into operation. hOWeVer,

it is recommended that only qualified service agents, using

appropriate test equipment, be allowed to service the heater.
As preliminary step, check wiring against diagram, check for

grounded, broken or loose wires. Check all wire ends to be sure

that they are making good contact.

electrical serVicing

LABeL ALL WIreS PrIOr TO DISCONNeCTION WheN

SerVICING CONTrOLS. WIrING errOrS CAN CAUSe

ImPrOPer AND DANGerOUS OPerATION.

VerIFy PrOPer OPerATION AFTer SerVICING.

start up conditions

smoke/odor
It is not uncommon to experience a small amount of smoke and

odor during the initial start-up. This is due to burning off of oil

from metal parts, and will disappear in a short while.
strange sounds
Possible noises due to expansion and contraction of some metal

parts during periods of heat-up and cool-down do not necessarily

represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area

during heating and cooling periods and should be considered

normal. See “Condensation” in this manual.
condensation
Whenever the water heater is filled with cold water, some

condensate will form while the burner is on. A water heater may

appear to be leaking when in fact the water is condensation.

This usually happens when:
a. A new water heater is filled with cold water for the first time.
b. Burning gas produces water vapor in water heaters,

particularly high efficiency models where flue temperatures

are lower.

c. Large amounts of hot water are used in a short time and the

refill water in the tank is very cold.

moisture from the products of combustion condense on the cooler

tank surfaces and form drops of water which may fall onto the

burner or other hot surfaces to produce a “sizzling” or “frying” noise.

operational conditions

smelly water
The water heater has at least one anode rod for corrosion

protection of the tank. Certain water conditions will cause a

reaction between this rod and the water. The most common

complaint associated with the anode rod is one of a “rotten egg

smell” in the hot water. The smell is a result of four factors which

must all be present for the odor to develop:

a. A concentration of sulfate in the supply water.

b. Little or no dissolved oxygen in the water.

c. A sulfate reducing bacteria which has accumulated

within the water heater (this harmless bacteria is

nontoxic to humans).

d. An excess of active hydrogen in the tank. This is caused

by the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater

models by replacing the anode(s) with one of less active material,

and then chlorinating the water heater tank and all water lines.
Contact the local water heater supplier or service agency for