Specifications – Raymarine 150/400 User Manual

Page 53

Advertising
background image

Specifications

45

Specifications

Course computer specifications

Nominal supply voltage:

Type 150/150G
Type 400/400G

12 V DC (fuse protected at 30 A)
12 V or 24 V DC (fuse protected at 40 A)

Operating voltage range:

Type 150/150G
Type 400/400G

10 V to 16 V DC
10 V to 32 V DC

Power consumption (standby)

300 mA

GyroPlus yaw sensor:

• Type 150G/Type 400G: internal GyroPlus fitted onto circuit board
• Type 150/Type 400: option of external GyroPlus or dealer-fit

internal GyroPlus

Operating conditions:

temperature range
relative humidity limit
water protection

-10°C to 55°C (14°F to 131°F)
80%
drip resistant when mounted vertically

Storage conditions:

temperature range
relative humidity limit

-5°C to 50°C (23°F to 122°F)
75%

Dimensions:

width
height
depth

307 mm (12.1 in)
195 mm (7.7 in)
70 mm (2.8 in)

Weight

2.1 kg (4 lb 7.5 oz)

Inputs

fluxgate compass, external GyroPlus yaw sensor, rudder position
sensor, NMEA 0183 v2.3 (x2), SeaTalk (x2), off switch, power,
drive solenoid return

Outputs

NMEA 0183 v2.3 (x2), SeaTalk (x2), drive motor, drive clutch

Raymarine drive compatibility:

Type 150/150G
Type 400/400G

all Type 1 12 V and Type CR1 12V drives/pumps
all Type 1, Type 2 and Type 3 drives/pumps (drive voltage must match
boat’s supply voltage)

Drive motor output:

Type 150/150G
Type 400/400G


continuous 18 A at 12 V
continuous 30 A at supply voltage

[specifications continue on next page]