No incoming line voltage or 24 volt, Ignitor lockout – Rheem HE80-130LP User Manual

Page 18

Advertising
background image

18

POSSIBLE CAUSE

1. No Input power.
2. Wiring disconnected
3. One or more wiring recep-

tacles disconnected from
control.

4. LED burned out.
5. Defective transformer.
6. Transformer wiring problem.

REMEDY

1. Apply Power
2. Check all wiring
3. Reconnect plugs on control.

Confirm all are fully seated.

4. Replace display board.
5. Replace transformer.
6. Repair transformer wiring.

NO INCOMING LINE VOLTAGE OR 24 VOLT

Line LED & 24 VAC LED Off

NOTE:
The transformer is of Class II variety and has an internal non-
replaceable fuse. If blown, a problem may exist with the control
which is affecting the transformer. In such cases, it is recom-
mended the control should be replaced as well.

POSSIBLE CAUSE

1. Broken ignitor element.
2. Ignitor unplugged.
3. Insufficient ignitor current
draw.

REMEDY

1. Replace ignitor element.
2. Plug in ignitor.
3. Monitor ignitor current draw.
See note below.

IGNITOR LOCKOUT

Ignitor Element LED Flashing

NOTE:
The ignitor current is monitored by pressing the blue button to
the left of the LEDs during the ignitor warm-up period or when
the ignitor element LED is illuminated. The 3-segment LED
display will show the actual ignitor current draw. The expected
ignitor current draw is from 2.5 to 4.5 amps.

LINE

K1

COMB
BLOWER

K5

IGNITER
ELEMENT

24

VAC

ECO/VENT

SWITCH

SWITCH

PRESSURE

GAS

VALVE

RLY 1

GAS

VALVE

RLY 2

GAS

VALVE

CONTROL

HEALTH

WATER

TEMPERATURE

K1

K5
K3

K4

K4

K3

CONTROL

ELECTRONICS

LINE

K1

COMB
BLOWER

K5

IGNITER
ELEMENT

24

VAC

ECO/VENT

SWITCH

SWITCH

PRESSURE

GAS

VALVE

RLY 1

GAS

VALVE

RLY 2

GAS

VALVE

CONTROL

HEALTH

WATER

TEMPERATURE

K1

K5
K3

K4

K4

K3

CONTROL

ELECTRONICS

Advertising
This manual is related to the following products: