Trouble shooting guide – Rheem HE80-130LP User Manual

Page 29

Advertising
background image

HOW T

TO O

OBTAIN S

SERVICE A

ASSISTANCE

Should you have any questions about your new water heater, or if it
requires adjustment, or routine maintenance, it is suggested that you
first contact your installer, plumbing contractor or previously agreed
upon service agency. In the event that the firm has moved, or is
unavailable, refer to the telephone directory commercial listings or
local utility for qualified service assistance.

Should your problem not be resolved to your complete satisfaction,
you should then contact the Manufacturer’s National Service
Department at the following address:

RHEEM MANUFACTURING COMPANY
2600 Gunter Park Drive East
Montgomery, Alabama 36109-1413

You may also obain technical assistance by calling
1-800-432-8373.

When contacting the manufacturer, the following information should
be made available:

1. Model and serial number of the water heater as shown on the rat-
ing plate attached to the jacket of the water heater.
2. Address where the water heater is located and can be seen.
3. Name and address of installer and any service agency who per-
formed service on the water heater.
4. Date of original installation and dates any service work was per-
formed.
5. Details of the problems as you can best describe them.
6. List of people, with dates, who have been contacted regarding your
problem.

NATURE OF TROUBLE

POSSIBLE CAUSES

SERVICE

No Hot Water

Manual switch turned off (if equipped)

Turn to ON

Blown service panel fuse or breaker

Replace or reset

See flashing LED light on display board

Improper or loose wiring to control board

Check and tighten
Reconnect electrical supply in proper polarity

Gas Valve turned "OFF"

Turn gas valve "ON"

Low gas pressure causes lockout

Check gas pressure when unit fires

Not enough gas pressure for demand of system

Increase pressure to 7" - 14" w.c. on inlet side of gas valve
Replace regulator

Bad gas meter or meter too small for load

Replace meter

Supply pipe is less that 3/4 inch diameter

Replace with 3/4 inch pipe

Gas regulator too close to heater

Must be at least 10 feet from heater

Venting restricted enough to cause lockout

Check and clear venting pipes and vent termination

Not Enough Hot Water

Thermostat set too low

Increase thermostat setting

Heater is undersized

Resize and compare

Water Too Hot

Thermostat setting too high

Lower thermostat setting

Slow Hot Water Recovery

Improper gas supply

Check gas pressure

Venting restricted - but not enough to cause lockout

Check and clear venting pipes and vent termination

Noisy Water Heater

Puffing on ignition

Adjust gas valve

Loud pop on ignition

Adjust gas valve

Huff and puff during operations

Adjust gas valve

Intermittent huffing and puffing

Check for re-circulation under venting

Excessive water pressure (just a little from the T&P)

Excessive water temperature (approx. 2/3 of tank
volume is on the floor)

Rusty Water

Excessive iron content

Have water analyzed. Install filter (if necessary).

Dielectric unions installed

Install non-dielectric unions

Water On Floor Around Unit

Condensate removal system is not working

Check condensate line for blockage
Check condensate line is directed to floor drain
Condensate pump not working (if equipped)
Drain line is "vapor locked". Install a vent in the condensate
drain line

Water heater is leaking

Cold in or hot out joints (connections)

Check joints and repair

T&P valve

Check, tighten and/or replace

Temperature/ECO probe

Check, tighten and/or replace

Inner tank has a pin hole

Replace water heater

Excessive Relief Valve
Operation

Check for open or closed system. Install thermal expansion
tank. Install proper expansion tank on cold side.
Check ECO/vent switch LED flashing; lower setting or replace
thermostat/ECO probe.

Rectify problem by diagnosing using the Display Board LED
chart

Electrical polarity is reversed. Green LED on display
board is not on.

Bad gas regulator before heater or gas regulator is
too small for load

(Includes banging, huffing and
puffing)

Trouble Shooting Guide

AP12158 Rev 1 (05/00)

Advertising