Controller enclosure, Control board, Roberts gordon – Roberts Gorden UltraVac NEMA 4 User Manual

Page 28: Ultravac™ c

Advertising
background image

ROBERTS GORDON

®

ULTRAVAC™ C

ONTROLLER

I

NSTALLATION

M

ANUAL

22

5.3 TCP/IP Communication Module

For remote on-site viewing of system status and
settings of any controller, use the TCP/IP communi-
cation module to connect the controllers to a Local
Area Network (LAN) via Ethernet cable. Any
computer on the LAN that has ULTRAVAC™ soft-
ware installed can be used to communicate with the
controllers.

The module must be mounted inside the
ULTRAVAC™ central controller (controller #1)
enclosure next to the control board. The power (5V)
for the module will come from the ULTRAVAC™
control board. The module will communicate to the
controller via regular phone wire from the RJ11 jack
on the module to the RS-232 direct connect port on
the control board. The module will relay the data

from the controller to computers on the LAN via
Ethernet cable plugged into the RJ45 jack on the
module. A setup procedure must be performed on
the module upon installation to create its IP address
on the LAN. The setup instructions can be found in
the ROBERTS GORDON

®

Software Manual.

For TCP/IP communication module wiring details, see
Page 23, Figure 16.

If multiple ULTRAVAC™ controllers are being used, the
additional controllers communicate to controller #1
through RS-485 communication wiring arranged
in-series from one controller to the next. See Page 25,
Section 5.5

. This allows multiple controllers to be

controlled from a PC through a single communication
package at the central controller.

FIGURE 15: TCP/IP Communication Module Mounting

Controller Enclosure

OUTPUT

1

L1

L2

GRD

GRD

L2

L1

OUTPUT

2

GRD

L2

L1

OUTPUT

3

GRD

L2

L1

OUTPUT

4

GRD

L2

L1

OUTPUT

5

GRD

L2

L1

OUTPUT

6

GRD

L2

L1

OUTPUT

7

GRD

L2

L1

OUTPUT

8

GRD

L2

L1

POWER

Line Voltage 120 V Wiring

Relay Board

Low Voltage 24 V Wiring

Mount TCP/IP module to enclosure
here or other suitable location within
the control board's compartment.

Do not mount module
in relay board compartment.

PSC CONTROLLER

+

-

1

+

-

2

+

-

4

+

-

3

+

-

5

+

-

6

+

-

7

+

-

8

+

-

+

-

REF

24VAC

L2

NO

NC C

NO

NC C

NO

NC C

NO

NC C

NO

NC C

NO

NC C

NO

NC C

NO

NC C

RS485 COMM

REF

+

-

1

+

-

2

+

-

3

+

-

4

METER INPUTS

UNIVERSAL INPUTS

IN

OUT

ADDRESS

RESET

10VDC

499 OHM

OFF
ON

OUT
IN

G

IN

OUT

G

G

G

+5

+32

AUX POWER

RS232 DIRECT

RI

CD

OH

CPU

L1

PWR

Control Board

Advertising