40 troubleshooting flow chart (continued) – Roberts Gorden UltraVac NEMA 4 User Manual

Page 46

Advertising
background image

ROBERTS GORDON

®

ULTRAVAC™ C

ONTROLLER

I

NSTALLATION

M

ANUAL

40

Troubleshooting Flow Chart (continued)

C

ons

u

lt

w

ir

ing instr

u

ctions

in 200 Ser

ies P

u

mp Man

u

al

(P/

N

1

27200

N

A) or EP

-300

Ser

ies P

u

mp Man

u

al (P/

N

1

27202

N

A) f

or r

e

ver

sal

instr

u

ctions

.

N

o

R

eplace f

ilt

er

s as necessar

y.

R

eplace the electr

odes

.

Ad

ju

st the g

ap or

replace the electr

ode

.

Ignition mod

u

le ma

y ha

ve

failed.

R

eplace mod

u

le

.

Electr

ode g

ap sho

u

ld

b

e

1/

8

".

Is the g

ap t

oo small?

N

o

Ye

s

Inspect the electr

odes on the

af

fect

ed

bu

rner

s

. Ar

e

the

y

bu

rned or damaged?

No

Ye

s

Co

u

plings ma

y

b

e inst

alled

impr

oper

ly

. Lined co

u

plings

sho

u

ld

b

e

u

sed f

or t

a

ilpipe

.

All co

u

plings sho

u

ld

b

e

sn

u

g ar

o

u

nd t

ub

e.

Mak

e s

u

re

that all

sensor set points ar

e

satisf

ied.

Do

bu

rner

s sh

u

t of

f af

ter the

call f

or heat is satisf

ied?

Ye

s

N

o

Chec

k f

or

b

loc

k

age in the

o

u

tside air s

u

ppl

y

or f

o

r

leaks in the s

y

s

tem.

R

eplace f

ilt

er

s as necessar

y.

N

o

Ye

s

Ar

e the f

ilt

er

s on the

bu

rn

er

s dir

ty

?

Is the r

o

tation of the

p

u

mp mot

or corr

ect?

Ye

s

N

o

Ad

ju

st s

y

st

em f

or pr

oper

vac

uu

m at the end

vent.

See C

ommissioning of the

CR

V

S

y

st

em f

or det

ails

.

Is the

vac

uu

m set

ting

too lo

w

?

N

o

Ye

s

Is the f

lame lo

w

?

N

o

Ye

s

N

o

Ye

s

Ar

e the f

ilt

er

s on the

bu

rner

s dir

ty?

Ye

s

N

o

Is the r

o

tation of the

p

u

mp mot

or corr

ect?

F

o

llo

w

bu

rner chec

k

pr

oced

u

re

gi

ven a

b

o

ve.

N

o

Ye

s

Ar

e ther

e an

y "dead"

bu

rn

er

s in a

b

ranch?

Is the

vac

uu

m set

ting

too lo

w

?

N

o

Ye

s

Is the s

y

st

em leaking

w

at

er?

N

o

Ye

s

Do the

bu

rner

s loc

k

o

u

t

int

er

mit

tentl

y?

N

o

Ye

s

Mak

e s

u

re

that all

sensor set points ar

e

satisf

ied.

Does the p

u

mp sh

u

t do

w

n

af

ter a 2 min

u

te

post-p

u

rge

per

iod?

Ye

s

N

o

TR

OUBLESHOO

T ENDS.

If pr

o

b

lems per

sist, cont

act

yo

u

r

R

OBER

TS GORDO

N

®

Independent Distr

ibu

to

r.

C

ont

act

Ro

b

er

ts-Gor

don at

www

.r

g-inc.com

Ad

ju

st s

y

st

em f

or pr

oper

vac

uu

m at the end

vent.

See C

ommissioning of the

CR

V

S

y

st

em f

or det

ails

.

Ye

s

C

ons

u

lt

w

ir

ing instr

u

ctions

in 200 Ser

ies P

u

mp Man

u

al

(P/

N

1

27200

N

A) or EP

-300

Ser

ies P

u

mp Man

u

al (P/

N

1

27202

N

A) f

or r

e

ver

sal

instr

u

ctions

.

Advertising