Installation, Horizontal installations – Regency FIREGENIE FG37-NG User Manual

Page 10

Advertising
background image

10

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

INSTALLATION

Diagram 2

HORIZONTAL INSTALLATIONS

Diagram 1

*Dia 2: Local codes or regulations may require

different clearances.

RESIDENTIAL AND MANUFACTURED HOMES/

MOBILE HOMES INSTALLATIONS

You will require the following components with your new Regency Rear Flued Room Sealed Freestanding Gas Stove. Please review your product

to make sure you have everything you need. In the event that you are missing any part, contact your dealer.

Note: These are the minimum pieces required.

Other parts may be required for your particular installation.

Minimum components for a Horizontal Installation:

946-110

Horizontal Termination Kit which includes:

1

946-201

6-5/8" dia. x 18" (168mm dia. x 457mm) Black Pipe

1

946-207

4" dia. x 18" (102mm dia. x 457mm) Aluminum Flue

1

946-584

Astro Riser Vent Terminal

1

946-202

Wall Penetration Heat Shield for Heat Sensitive walls

(Wall Thimble) (2 pcs)

1

640-545

Decorative Wall Trim (Black)

1

948-128

Tube Mill-Pac

Screws

Optional Components:

946-204

45

o

Elbow - 6-5/8" (168mm) Black pipe

and 4" (102mm) Aluminum Flue

946-205

Vinyl Siding Shield for Riser Vent

Terminal

946-208/P

Flue Guard

940

Square Wall Thimble Cover*

942

Wall Penetration

Heat Shield*

* Simpson Dura-Vent components

1) Set the unit in its desired location. Check to

determine if wall studs are in the way when

the fluing system is attached. If this is the

case, you may want to adjust the location

of the unit.

2) Assemble the desired combination of pipe

and elbow to the appliance adapter with

pipe seams oriented down. Offset the pipe

seams as double seams in one place will

cause the outer pipe to take an oval shape.

Kit comes complete with 18" (457mm) of

straight flue - 6-5/8" (168mm) dia. black

outer pipe and 4" (102mm) dia. inner flue.

3) With the pipe attached to the stove, slide the

stove into its correct location, and mark the

wall for a 9-1/2" (241mm) (inside dimen-

sions) round hole. The center of the round

hole should line up with the centerline of the

horizontal pipe, as shown in diagram 1. Cut

and frame the 9-1/2 (241mm) round hole in

the exterior wall where the flue will be

terminated. If the wall being penetrated is

constructed of non-combustible material,

i.e. masonry block or concrete, a 7" (178mm)

diameter hole is acceptable.

Note:

a) The horizontal run of flue should have

a 1/4 inch (6mm) rise for every 1 foot

(305mm) of run towards the termina-

tion. Never allow the flue to run down-

ward. This could cause high tempera-

tures and may present the possibility of

a fire.

b) The location of the horizontal flue termi-

nation on an exterior wall must meet all

local and national building codes, and

must not be blocked or obstructed. For

External Flue Terminal Locations, see

diagram on page 7.

c) Snorkel Terminations:

For installations requiring a vertical rise

on the exterior of the building, Astro

Riser Vent Terminations as shown in

Dia. 2 is available. Follow the same

installation procedures as used for

standard Horizontal Termination.

NEVER install the Astro Riser vent up-

side down.