Installation, Installation checklist, Locating your regency gas stove – Regency FIREGENIE FG37-NG User Manual

Page 6: Clearances to combustibles, Combustion and ventilation air

Advertising
background image

6

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

14) Under no circumstances should any solid

fuels (wood, paper, cardboard, coal, etc.)

be used in this appliance.

15) The appliance area must be kept clear and

free of combustible materials, (gases and

other flammable vapours and liquids).

INSTALLATION

CHECKLIST

1) Check Clearances to Combustibles (page

6), location of unit (page 6) and fluing

requirements (pages 6-9).

2) Install fluing: Check all fluing requirements,

pages 8-12.

3) Make gas connections, page 12. Test the

pilot. Must be as per diagram, pages 15 &

22.

4) If necessary, convert from NG to LPG (page

13).

5) Install log set, page 15.

6) Install Front Door Front, page 16.

7) Test Gas Pressure, page 17.

8) Install Louvres, page 17.

9) Install optional Remote Control, page 18.

10) Final check, page 18.

Before leaving this unit with the customer, the

installer must ensure that the appliance is firing

correctly and operation fully explained to

customer.

This includes:

1) Clocking the appliance to ensure the cor-

rect firing rate (rate noted on label) after

burning appliance for 15 minutes.

2) If required, adjusting the primary air to

ensure that the flame does not carbon. First

allow the unit to burn for 15-20 min. to

stabilize.

CAUTION: Any alteration to the product

that causes sooting or carboning that

results in damage is not the responsibil-

ity of the manufacturer.

LOCATING YOUR

REGENCY GAS STOVE

When selecting a location for your stove, en-

sure that the clearances listed above are met as

well as ensuring that there is adequate acces-

sibility for servicing and proper operation.

For Flu Termination requirements, see page 7.

This appliance is Listed for bedroom installa-

tions when used with a Listed Millivolt Thermo-

stat. Some areas may have further require-

ments, check local codes before installation.

This appliance is Listed for Alcove installations,

maintain minimum Alcove clearances as fol-

lows, minimum ceiling height of 1.7m, minimum

width of 1.0m and a maximum depth of 0.9m.

INSTALLATION

Use the minimum clearances shown in the

diagrams below:

FG37-NG & FG37-LPG Clearances

A Side Wall to Unit

190 mm

B Back Wall to Unit

76 mm

E Side Wall to Unit

114 mm

FG37-NG & FG37-LPG

Reference Dimensions

C Floor to Flue Centerline

635 mm

D Side Wall to Flue Centerline 521 mm

A) Cross Corner

B) Flush with Wall/Alcove

C) Flat on Wall Corner

D) Flat on Wall

CLEARANCES TO

COMBUSTIBLES

The clearances listed are MINIMUM distances.

Measure the clearance to both the appliance

and the chimney connector. The farthest

distance is correct if the two clearances

do not coincide. For example, if the appliance

is set as indicated in one of the diagrams but the

connector is too close, move the stove until the

correct clearance to the connector is obtained.

This appliance may be installed only with the

clearances as shown in the situations pictured.

Do not combine clearances from one type

of installation with another in order to

achieve closer clearances.

This unit can be installed on a solid combustible

surface like a wood floor. This unit can also be

installed directly on carpeting or vinyl when the

bottom pedestal cover plate (provided with unit)

is installed.

COMBUSTION AND

VENTILATION AIR

The combustion air from this appliance is drawn

from outside the building through the outer flue.

Extra provision for combustion air inside

the room is not required.

Minimum ceiling height

is 914 mm from top of

unit.