FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

9

INSTALLATION

FLUING ARRANGEMENTS - VERTICAL TERMINATIONS

FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES

Offset to Vertical Terminations

If connecting to a Dura-Vent sys-

tem, the Adapter to Dura-Vent #

640-994 is required.

Vertical Terminations

with Co-linear Flex System

The shaded area in the diagram shows the allowable vertical

terminations installed in a masonry chimney. All vertical flue

installations require the Flue Restrictor to be set to 32mm open. All

Vertical Flue Terminals must be Simpson Dura Vent (Abey Australia)

DV 980 MAS (Australian Modified.)

Vertical Terminations

using Dura-Vent Fluing System

The shaded areas in the two diagrams below show all allowable

combinations of straight vertical and offset to vertical runs with

vertical terminations. Maximum one 90

o

elbow. All vertical and

offset to vertical flue installations require Flue Restrictor to be set to 32mm

open. If the flue is ENCLOSED in a chase (min. size 229mm x 229mm)

maintain a 32mm clearance to combustibles. All Vertical Flue Terminals

must be Simpson Dura Vent (Abey Australia) DV 980 MAS (Australian

Modified.)

Straight Vertical Terminations

Flue Restrictor Position

Vent Restrictor

Vent

Restrictor

Plate

Vent Restrictor

(fully open)

Vent

Restrictor

Plate

44.5mm

44.5mm

32mm

32mm

To set the Flue restriction

as indicated in the diagram,

simply loosen the screws

and push the flue restrictor

plate to the correct position.

Tighten the screws.

216mm

9.1m

Max.

3.2m

Min.

1

1

1

2

4

5

6

7

8

2

1

3

9

Horizontal Distance (meters)

V

ertical

Height

(meters)