Installation, Gas connection, Vertical termination with co-linear flex system – Regency FIREGENIE FG37-NG User Manual

Page 12

Advertising
background image

12

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

System Data - FG37

Burner Inlet Orifice Sizes:

NG

#37

LPG

#52

Max. Input Rating

31.7 mj

Min. Input Rating

16 mj

Supply Pressure

NG

min. 1.13 kPa

LPG

min. 2.75 kPa

Manifold Pressure

NG

.89 kPa

LPG

2.55 kPa

GAS CONNECTION

The gas connection is a 1/2" (13mm) NPT Male

Thread. Copper can be used or other con-

nections approved by AG 604.

When using copper or flex connectors use

only approved fittings. Always provide a union

so that gas lines can be easily disconnected for

burner and/or valve servicing. Flare nuts for

copper lines are usually considered to meet

this requirement.

Important: Always check for gas leaks

with a soap and water solution or gas

leak detector. Do not use open flame for

leak testing.

Note: Prior to any pressure testing of

the gas supply piping system that

exceeds test pressures of 3.45

kPa, this appliance must be dis-

connected from the piping sys-

tem. If test pressures equal to or

less than 3.45 kPa are used then

this appliance must be isolated

from the piping system by clos-

ing its individual manual shut-off

valve during the testing.

VERTICAL TERMINATION WITH

CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING

A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the

full length of the chimney. See the Fluing Arrangements chart on page 9 for minimum and maximum

flue lengths. See chart below for minimum distances from roof. Periodically check that the flue

is unrestricted.

Masonry chimneys may take various contours which the flexible liner will accommodate.

However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical Termination Cap

948-305

3" Flex - 35 ft.

640-994

FG37 Dura-Vent Adapter

946-563

Co-Axial to Co-Linear Adapter Kit

which contains the following:

Co-linear Flex Adapter (270-585)

Outer Pipe (946-257)

Inner Pipe Adapter (946-219)

Approved Caps

980

Vertical Termination Cap

923GK

3" (76mm) Co-linear Adapter

with flashing

923GK

3" (76mm) Co-linear Adapter

with flashing

INSTALLATION

Advertising
This manual is related to the following products: