Installation – Regency FIREGENIE FG37-NG User Manual

Page 11

Advertising
background image

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

11

Diagram 5

Diagram 4

Below Grade Snorkel Installation

If the Snorkel Termination must be installed

below grade, i.e. basement application,

proper drainage must be provided to pre-

vent water from entering the Snorkel Ter-

mination. Refer to Dura-Vent Installation

instructions for details.. Do not attempt to

enclose the Snorkel within the wall, or any

other type of enclosure.

4) Install wall penetration heat shield in the center

of the 9-1/2" (241mm) round hole and attach

with wood screws. The four wood screws

provided should be replaced with appropriate

fasteners for stucco, brick, concrete, or other

types of sidings. Dia. 3.

NOTE: For Snorkel terminations in ABOVE

grade installations, follow national or

local code requirements.

Diagram 3

5) If installing termination on a siding covered

wall, a vinyl siding standoff or furring strips

must be used to ensure that the termination is

not recessed into the siding. Dia. 3.

6) Take the Riser Vent terminal and separate the

Backing Plate from the Riser Vent Front by

removing 8 screws as shown in diagram 4.

7) Install the Backing Plate into the wall

penetration heat shield and attach us-

ing 4 screws. Dia. 4.

8) Connect all pipe sections to unit and

install into wall:

a) Measure pipe length required and

cut to length. Hint: use the cut end

of the 6-5/8" (168mm) dia. outer

pipe at the flue terminal end.

b) Push the pipe sections completely

together, the minimum pipe overlap

is 1-1/4" (32mm). Secure all outer

pipe joints by using at least two

screws. Locate the screws at the

bottom of the pipe so that the screw

heads are hidden on the final instal-

lation. Apply sealant "Mill-Pac" to

inner pipe and high temp silicone

sealant or "Mill-Pac" to outer pipe on

every joint.

Hint: Apply sealant to female end.

c) Before connecting the flue pipe to

the flue termination, slide the black

decorative wall thimble cover over

the flue pipe, then slide the Wall

Penetration Heat Shield (Part # 946-

202) over the flue pipe. Dia. 3.

d) Slide the appliance and flue assem-

bly towards the wall carefully in-

serting the flue pipe into the riser

vent terminal assembly. It is impor-

tant that the flue pipe extends into

the Riser Vent Backing Plate a suf-

ficient distance so as to result in a

minimum pipe overlap of

1-1/4 inches (32mm). Secure the

connection between the flue pipe

and the flue cap by attaching the

two sheet metal strips extending

from the Riser Vent Backing Plate

into the outer wall of the flue pipe.

Use two aluminum screws provid-

ed to connect the strips to the pipe

section. Bend any remaining por-

tion of the sheet metal strip back

towards the flue cap and cut off

any excess, it will be concealed by

the decorative wall thimble cover.

See diagram 5.

8) Slide the decorative wall thimble up to the

wall surface being careful not to scratch

the paint. See diagram 5.

9) Back outside: Apply sealant to the 4" (102mm)

inner flue and slide the Riser Vent Front into

the Backing Plate and fasten with 8 screws.

IMPORTANT:

When connecting the pipe to the Riser

Vent, apply Mill-Pac to the inner pipe

on the Riser Vent Terminal, around

the bead. Ensure that the flue pipe is

pushed past the bead for a secure fit.

INSTALLATION

10) Seal around the outer edge of the Riser

Vent Backing Plate.