Omega CNiS8DV User Manual

Page 64

Advertising
background image

60

Cycle Time
1 to 199 seconds; set to 0 for on/off
operation

Gain
0.5 to 100% of span; Setpoints 1 or 2

Damping
0000 to 0008

Soak
00.00 to 99.59 (HH:MM), or off

Ramp to Setpoint
00.00 to 99.59 (HH:MM), or off

Auto Tune
Operator initiated from front panel

CONTROL OUTPUT 1 & 2
Relay
250 Vac or 30 Vdc @ 3 A
(Resistive Load); configurable for
on/off, PID and Ramp and Soak

Output 1: SPDT type, can be
configured as Alarm 1 output

Output 2: SPDT type, can be
configured as Alarm 2 output

SSR
20-265 Vac @ 0.05-0.5 A
(Resistive Load); continuous

DC Pulse
Non-Isolated; 10 Vdc @ 20 mA

Analog Output (Output 1 only)
Non-Isolated, Proportional 0 to 10 Vdc
or 0 to 20 mA; 500 Ω max

NETWORK AND COMMUNICATIONS
(Optional -C24, -C4EI, -EI not
available with excitation)
Ethernet:
Standards Compliance
IEEE 802.3 10Base-T
Supported Protocols: TCP/IP, ARP,
HTTPGET

RS-232/RS-422/RS-485/MODBUS:
Selectable from menu; both ASCII and
modbus protocol selectable from
menu. Programmable 300 to 19.2 K
baud; complete programmable setup
capability; program to transmit current
display, alarm status, min/max, actual
measured input value and status.
RS-485
Addressable from 0 to 199
Connection
Screw terminals

ALARM 1 & 2 (programmable):
Same as Output 1 & 2

Operation
High/low, above/below, band,
latch/unlatch, normally open/normally
closed and process/deviation;
front panel configurations

ANALOG OUTPUT (programmable)
Non-Isolated, Retransmission 0 to
10 Vdc or 0 to 20 mA, 500 Ω max
(Output 1 only). Accuracy is +1% of
FS, for Scaling Gain from 0.03 to
100 mV per count

EXCITATION
(optional in place of Communication)
5 Vdc @ 40 mA
10 Vdc @ 60 mA
Not available for Low Power Option

INSULATION
Power to Input/Output, (Reinforce)

2300 Vac per 1 min. test

1500 Vac per 1 min. test,
(Low Voltage/Power Option)

Power to Relays/SSR Outputs

2300 Vac per 1 min. test

Relays/SSR to Relay/SSR Outputs

2300 Vac per 1 min. test

RS-232/485 to Inputs/Outputs

500 Vac per 1 min. test
(no isolation is provided for Strain units)

Advertising