4 - 29

Modem Command Reference

\Nn — Operation Mode Control

Parameters

0, 1, 2, 3, 4, or 5

Default

3

Selects the operating mode the modem uses while connected (see &Qn
command).

Examples

AT\N0

Selects Normal (speed buffering) mode. This option

takes effect at physical connection time.

AT\N1

Same as AT\N0.

AT\N2

Selects reliable link mode. This defines the modem-

to-modem connection to require error correction
connection. If an attempt to establish the reliable
link fails, the modem disconnects.

AT\N3

Selects auto-reliable link mode. The modem will

attempt an error-correction connection but will
fallback to Normal mode if unable to establish an
error correcting connection. This command takes
effect at physical connection time only.

AT\N4

Selects LAPM error-correction mode. The modem

will attempt a LAPM error-correction connection. If
the attempt fails, the modem disconnects.

AT\N5

Selects MNP error-correction mode. The modem will

attempt a MNP error-correction connection. If the
attempt fails, the modem disconnects.

%Cn — Compression Control

Parameters:

0, 1, 2, or 3

Default

3

Enables or disables data compression negotiation. The modem can only
perform data compression on an error-correcting link.

Examples

AT%C0

Disables data compression

AT%C1

Enables MNP 5 data compression

AT%C2

Enables V.42bis data compression

AT%C3

Enables both MNP 5 and V.42bis data compression