Ositech comm Trumpcard Data/Fax Modem User Manual

Page 84

Advertising
background image

5 - 6

Trumpcard 14400/28800 Modem

Section Five

Remote Digital Loopback with Self-
Generated Pattern

This procedure tests the remote Modem port, the telephone line, the local
serial and Modem ports. The test is only functional when the Modem is in
direct mode (&Q0) and the COM port baud rate is set to 14400 bps
(Trumpcard 14400) / 28800 bps (Trumpcard 28800) or less.

This test is similar to the Remote Digital Loopback test.

In this test, the local Modem sends the remote Modem a special test data
sequence and the remote Modem echoes the data back. The local
Modem examines the returned data and establishes an error count each
time a mismatch is detected.

To run this test:

1. Establish a connection with a remote Modem.

2. Enter

AT&T4 [ENTER]

to ensure that the remote operator has set the

Modem to accept a Remote Digital Loopback request.

3. Enter

AT&T7 [ENTER]

to initiate the remote digital loopback test. The

Modem will send a test pattern to the remote Modem.

4. Enter

AT&T0 [ENTER]

to end the test. The Modem will return a three-

digit number showing the test results. If the result is 000, the local and
remote modems, and the telephone line have passed the test.

Advertising