Omega Vehicle Security LVP-51 Series User Manual

Page 11

Advertising
background image

 

11 

 

WIRING (continued) 

Step Six 

Wiring  the  Relay  Output:    The  LVP‐51‐R  requires  12  ‐  36  VDC  power  to  operate  the  sensor  and  switch  the 
relay.  All illustrations below identify a Dry switch state as the normal position of the relay. 

Switching a Normally Open DC Load:  
The  Red  wire  connects  to  Positive  (+)  of  the  power 
supply  and  the  Black  wire  connects  to  Negative  (‐). 
The  LOAD  can  be  attached  to  either  the  Green  or 
White wires.  Complete the circuit by connecting the 
Green  to  (+)  VDC  power  or  White  to  (‐)  VDC  power 
(see illustration below). 

Switching a Normally Closed DC Load:   
The  Black  wire  connects  to  Positive  (+)  of  the  power 
supply and the Red wire connects to Negative (‐).  The 
LOAD  can  be  attached  to  either  the  Green  or  White 
wires.  Complete the circuit by connecting the Green 
to  (+)  VDC  power  or  White  to  (‐)  VDC  power  (see 
illustration below). 

 

 

Sensor Power  
[RED & BLK wires] / 36 VDC Max. 
5 ±1mA Dry / 20 ±1mA Wet 

Relay Rating 
[GRN & WHT wires] / 60 VA 

 

Switching a Normally Open AC Load:   
The  Red  wire  connects  to  Positive  (+)  of  the  DC 
power  supply  and  the  Black  wire  connects  to 
Negative  (‐).    The  LOAD  can  be  attached  to  the 
Green wire and the Hot of the VAC power.  Connect 
the  White  to  the  Neutral  of  the  VAC  power  (see 
illustration below). 

Switching a Normally Closed AC Load:   
The Black wire connects to Positive (+) of the DC power 
supply and the Red wire connects to Negative (‐).  The 
LOAD can be attached to the Green wire and the Hot of 
the  VAC  power.    Connect  the  White  to  the  Neutral  of 
the VAC power (see illustration below). 

Sensor Power  
[RED & BLK wires] / 36 VDC Max. 
5 ±1mA Dry / 20 ±1mA Wet 

Relay Rating 
[GRN & WHT wires] / 60 VA 

 

 

 