Omega Vehicle Security LVP-51 Series User Manual

Page 8

Advertising
background image

 ELECTRICAL 

Step Five 

Supply Voltage:  The supply voltage to the LVP‐51‐R level switch should never exceed a maximum of 36 VDC.  
OMEGA  ENGINEERING  controllers  have  a  built‐in  13.5  VDC  power  supply  which  provides  power  to  all  of 
OMEGA  ENGINEERING’s  electrically  powered  sensors.    Alternative  controllers  and  power  supplies,  with  a 
minimum output of 12 VDC up to a maximum output of 36 VDC, may also be used with the level switch. 

Required  Cable  Length:    Determine  the  length  of  cable  required  between  the  level  switch  and  its  point  of 
termination. Allow enough slack to ensure the easy installation, removal and/or maintenance of the sensor.  
The  cable  length  may  be  extended  up  to  a  maximum  of  1000  feet,  using  a  well‐insulated,  14  to  20  gauge 
shielded four conductor cable. 

Wire Stripping:  Using a 10 gauge wire stripper, carefully remove the outer layer of insulation from the last 1‐
1/4" of the sensor's cable.  Unwrap and discard the exposed foil shield from around the signal wires, leaving 
the  drain  wire  attached  if  desired.  With  a  20  gauge  wire  stripper,  remove  the  last  1/4"  of  the  colored 
insulation from the signal wires. 

Signal  Outputs  (Current  sensing):    The  standard  method  used  by  OMEGA  ENGINEERING  controllers;  this 
technology uses only two wires (Red and Black). The sensor draws 5 mA when it is dry and 19 mA when wet. 
NC/NO status must be set by the controller.  The White and Green wires are not used. 

 

 

 

 

Advertising