Appendix B: Query

User Manual and Technical Guide The O'Neil microFlash Series of Printers

ESC{CF?}

Configuration

Query Format:

ESC{CF?}

Reply Format:

{CF!L:x; B:x; P:x; N:x; H:x;D:x;Y:x;S:x;T:x}

Function:

Returns information about configurable options
.

Reply Example:

{CF!L:LP;B:096;P:N;N:8;H:B;D:+10%;

Y:1;S:Y;T:0060}

Reply Explanation:

CF!

This is a reply to a Configuration query.

L:LP;

The default mode is Line Printer.

B:096;

The baud rate is 9600.

P: N;

No parity is set.

N:8;

There are 8 data bits.

H:B;

Hardware and software handshaking are enabled.

D:+10%;

The darkness (burn time) is set to +10%.

Y:1;

The paper is 1 ply.

S:Y;

The sound is on.

T:0060

The time-out is set for 60 seconds.

Query

Reply

Definition

L

LP, EZ

Default mode -Line Printer or Easy Print (EZ)

B

012,024,
048,096,
192,384

Baud rate = 1200, 2400, 4800, 9600, 19.2K or 38.4 baud

P

N,E,O

Parity is None, Even, or Odd

N

7,8

Number of Data Bits is 7 or 8

H

N,H,S,B

Handshaking = None, Hardware, Software, or Both

D

-25%
...+35%

Darkness can be -25%, -20%, -15%, -10%, -05%, +10%,
+15%, +20%,25%, +35%

Y

1,2

Ply of paper = 1 or 2

S

Y,N

Beeper (Sound) = Y (Yes) or N (No)

T

nnnn

Timeout value in seconds (9999 = always on)