Command Name: Windowing

Usage:

Sets the imaging window size.

Description:

You may optimize the LH2 decode zone if the application only

requires one barcode format. If the size and density of the barcodes

to be scanned are consistent, please select the setting below that

best describes your environment.

Default:

The window size is set to 640 x 1024 pixels

Programming Code:

Serial Command:

1D & 2D Bar Codes

P%53#640<┘

640 X 1024 Pixels (Default)

P%54#1024<┘
P%C7#640<┘
P%C8#1024<┘

Options:
Programming Code:

Serial Command:

1D Bar Codes Only

P%53#200<┘

200 x 1024 Pixels

P%c7#200<┘

Small 2D Bar Codes

P%53#480<┘

480 x 480 Pixels

P%54#480<┘
P%C7#480<┘
P%C8#480<┘