Use sl d-series components only – Quadra-Fire QV32-A User Manual

Page 14

Advertising
background image

18

V

H

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6' MAX. (1.86m)

4' MIN. (1.22m)

8' MAX. (2.4m)

V+H=40' MAX. (12.4m)
H = 8' MAX. (2.4m)

Figure 12. Venting with One 90° Elbow

Use D-Series components only.

V

H

Figure 13. Venting with One 90° Elbow

V (MIN.)

90

o

Elbow on Top

1 FT (305mm)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
5 FT (1.52m)

Use SL D-Series

components only.

VENTING WITH ONE (1) 90

o

ELBOW NATURAL GAS

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

H (MAX.)

2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)

VENTING WITH ONE (1) 90

o

ELBOW PROPANE

V (MIN.)

H (MAX.)

90

o

Elbow on Top

NOT ALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

H

V

Note: There MUST be a 25% reduction
in total H when using flex vent, except
when using the simple up and out
installation (see Figure 9).

Note: There MUST be a 25% reduction
in total H when using flex vent, except
when using the simple up and out
installation (see Figure 9).