Step 2. framing the fireplace – Quadra-Fire QV32-A User Manual

Page 9

Advertising
background image

13

Figure 5.

Framing Dimensions

Framing should be
constructed of 2 X 4
lumber or heavier.

WARNING:
To ensure proper clearances the front
framing header must be installed on its
narrow edge and to the front of the frame.

The framing headers may rest
on the fireplace stand-offs.

VENT

FRAMING

HOLE

E

D

Model

A

B

C

D

E *

QV36-A

42”

38 1/4”

16 1/4”

41”

27 7/8”

QV32-A

37”

33”

16 1/4”

36 1/2” 24 3/8”

A

B

C

Step 2. Framing the Fireplace

Fireplace framing can be built before or after the fireplace
is set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.

*The center of the framing hole is one (1)
inch (25.4mm) above the center of the
horizontal vent pipe.

WALL STUD

NON-COMBUSTIBLE ZONE

IS DEFINED BY 3” ABOVE THE

ELBOW FOR THE ENTIRE

WIDTH AND DEPTH (BEHIND THE

FRONT HEADER) OF THE FIREBOX.

3 1/2”

3

‹