Quadra-Fire QV32-A User Manual

Page 20

Advertising
background image

24

Use SL D-Series

components only.

VENTING WITH THREE (3) 90

o

ELBOWS NATURAL GAS

H + H

1

MAX. = 16 FT (4.8m) V + V

1

+ H + H

1

MAX. = 40 FT (12.2m)

MODEL QV36-A

H + H

1

(MAX.)

2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)

VENTING WITH THREE (3) 90

o

ELBOWS PROPANE

H + H

1

MAX. = 16 FT (4.8m) V + V

1

+ H + H

1

MAX. = 40 FT (12.2m)

MODEL QV32-A

V (MIN.)

H + H

1

(MAX.)

90

o

Elbow on Top

NOT ALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

MODEL QV36-A

H + H

1

(MAX.)

NOT ALLOWED
2 FT (610mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)

MODEL QV32-A

V (MIN.)

H + H

1

(MAX.)

90

o

Elbow on Top

2 FT (610mm)

1 FT (305mm)

3 FT (914mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

Figure 19. Venting with three 90° elbows

V

1

H

1

H

V

Note: There MUST be a 25% reduction
in total H when using flex vent, except
when using the simple up and out
installation (see Figure 9).