Quadra-Fire QV32-A User Manual

Page 17

Advertising
background image

21

Figure 16. Venting with Two 90° Elbows

Use SL D-Series

components only.

VENTING WITH TWO (2) 90

o

ELBOWS NATURAL GAS

H MAX. = 16 FT (4.8m) V + V

1

+ H MAX. = 40 FT (12.2m)

H (MAX.)

2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)

VENTING WITH TWO (2) 90

o

ELBOWS PROPANE

H MAX. = 16 FT (4.8m) V + V

1

+ H MAX. = 40 FT (12.2m)

V (MIN.)

H (MAX.)

90

o

Elbow on Top

NOT ALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

V (MIN.)

90

o

Elbow on Top

1 FT (305mm)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
5 FT (1.52m)

H

V

V

1

Note: There MUST be a 25% reduction
in total H when using flex vent, except
when using the simple up and out
installation (see Figure 9).