Warning, 3100 wood stove series (acc), B. clearances to combustibles (ul and ulc) – Quadra-Fire 3100 31M-ACC-MBK User Manual

Page 11

Advertising
background image

March 2, 2007

7033-277C

Page 11

3100 Wood Stove Series (ACC)

R

B. Clearances to Combustibles (UL and ULC)

BACKWALL / SIDEWALL

A

B

C

D

E

F

E

F

CORNER INSTALLATION

G

G

H

*

90° OFF TOP
UP & OUT CEILING
CLEARANCE

STOVE TO CEILING
CLEARANCE

C

D

ALCOVE TOP VIEW

G

A

B

ALCOVE SIDE VIEW

NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction

Fire Risk.

• Comply with all minimum clearances to

combustibles as specifi ed.

• Failure to comply may cause house fi re.

WARNING

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.

A

B

C

D

E

F

G

H

INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top

SINGLE WALL PIPE

Flat Top Model

15.25 (387) 11.75 (298) 25.5 (648)

16 (406)

8 (203)

17 (432)

48 (1220)

12 (305)

Step-Top Model

12 (305)

8.5 (216)

22 (559)

12.5 (318)

5.5 (140

14.5 (368)

48 (1220)

12 (305)


DOUBLE WALL PIPE

Flat Top Model

10.5 (267)

6.5 (165)

22 (559)

13 (330)

6.5 (165)

15.5 (394)

48 (1220)

9 (229)

Step-Top Model

10 (228)

6 (152)

20.5 (521)

11 (279)

4 (102)

13 (330)

48 (1220)

9 (229)


INSTALLATION: 90° Elbow Off Top of Stove Through Backwall

SINGLE WALL PIPE

Flat Top Model

12 (305)

8.5 (216)

22 (559)

13 (330)

8 (203)

17 (432)

48 (1220)

12 (305)

Step-Top Model

10 (254)

6 (152)

20.5 (521)

11 (279)

5.5 (140)

14.5 (368)

48 (1220)

12 (305)


DOUBLE WALL PIPE

Flat Top Model

8 (203)

4.5 (114)

17.5 (445)

8.5 (216)

6.5 (165)

15.5 (394)

48 (1220)

9 (229)

Step-Top Model

10 (254)

6 (152)

20.5 (521)

11 (279)

4 (102)

13 (330)

48 (1220)

9 (229)

INSTALLATION: ALCOVE

Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed

factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove
shall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of unit, and the referenced clearances.
*In Canada must comply with CAN/ULC-S269 M87 for the 650

o

C Factory-built chimney.

DOUBLE WALL PIPE

Flat Top Model

11.75 (298) 8.25 (210) 23.5 (597) 14.5 (368)

N/A

N/A

48 (1220)

*

Step-Top Model

10 (254)

6.5 (152)

20.5 (521)

11 (279)

N/A

N/A

48 (1220)

*

* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED

SERVICE / MAINTENANCE TIP

In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of stove in
order to remove the tubes with the stove in place. If space
is not available, the stove will have to be disconnected from
the chimney to proceed with the tube replacement.

Advertising