Warning – Quadra-Fire 3100 31M-ACC-MBK User Manual

Page 14

Advertising
background image

Page 14

7033-277C

March 2, 2007

R

3100 Wood Stove Series (ACC)

B. Outside Air Kit Installation

1. Remove all materials from packing box.

2. Using a #2 Phillips screw driver attach the fl ex adapter

to the stove using 4 screws. Figure 14.1

3. Remove circular” knock-out” in the base of the pedestal.

4.

Floor & Rear Installation: Cut a 4 inch (102mm)
hole in outside wall or fl oor to accommodate outside
air piping. Use 4 inch (102mm) aluminum metal fl ex or
rigid piping to directly connect outside air to appliance
intake. Use the supplied termination cap with a rodent
screen. Seal between the wall (or fl oor) and the pipe
with silicone to prevent moisture penetration.

Items Needed for Installation (not supplied)

• 4 inch fl ex aluminum pipe, or if using alternate material,

then it shall be made from durable, non-combustible,
heat resistant material up to 350

o

F. Cut the pipe to

the required length for your installation.

• Phillips head screw driver

Silicone

sealant

• Drills and saws necessary for cutting holes through

the wall or fl ooring in your home.

Figure 14.1 - Floor & Rear Installation

A source of air (oxygen) is necessary in order for combus-
tion to take place. Whatever combustion air is consumed
by the fi re must be replaced. Air is replaced via air leak-
age around windows and under doors. In homes that have
tightly sealed doors and windows, an outside air source is
needed. An optional Outside Air Kit is available.

Flex Line

Wire Tie

Wire Tie

Flex Adapter

Terminatio
Cap

Remove circular
“knock-out” in base
of pedestal.

WARNING

Do not draw outside combustion air from:

• Wall,

fl oor or ceiling cavity

• Enclosed space such as an attic or garage

• Close proximity to exhaust vents or

chimneys

Fumes or odor may result

Fire Risk.

Asphyxiation Risk.

Asphyxiation Risk.

Outside air inlet must be located to prevent block-
age from:

• Leaves

Snow or ice

• Other

debris

Block may cause combustion air starvation

Smoke spillage may set off alarms or irritate sensi-
tive individuals.

WARNING

Asphyxiation Risk.

Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust fl ue.

Fire will not burn properly

Smoke spillage occurs when door is opened due

to air starvation.

WARNING

Included in OAK-ACC:

Termination cap, (2) wire ties, flex
adapter, and fasteners

Included in SRV7033-041:

Cover plate and sealing rope (see

Floor Installation Alternative below,
Figure 14.2)

Figure 14.2 - Floor Installation Alternative

Cover
Plate

Rope to Seal
Pedestal

5. Floor Installation Alternative: In some instances you

may not be able to install the fl ex pipe as show in Figure
14.1.
If that is the case, you will need to order SRV7033-
041 which includes a cover plate and sealing rope as
shown in Figure 14.2. The goal is to seal the pedestal
so no room air can leak into the pedestal.

Advertising