Troubleshooting

With proper installation, operation, and maintenance your woodstove
will provide years of trouble-free service. If you do experience a prob-
lem, this troubleshooting guide will assist a qualifi ed service person in
the diagnosis of a problem and the corrective action to be taken.

Diagnostic Question

Possible Causes of Condition

Solutions

Are the air controls open?

No draft

No combustion air

Open air controls

Is there enough paper?

Insuffi cient heat to ignite kindling

Use more paper

Is there enough kindling?
Is the kindling dry?

Insuffi cient heat to ignite fuel

Use drier kindling

Is there enough or too much wood?
Is it too large?
Is it dry enough?

• Insuffi cient heat to establish draft
• Insuffi cient air passage
• Insuffi cient surface area
• Ignition temperature high due to

moisture

Use small split wood that is well sea-
soned (split, covered on top minimum 6
months, preferably a year)

Are there adequate air spaces
between fuel pieces?

Insuffi cient combustion air and
exposed surface area

Arrange kindling and wood for air move-
ment

Is the chimney pre-warmed?

Exposed, cold chimney downdrafting

Use lighted rolled newspaper at fl ue
opening to start upward air movement

Is there smoke in the house?

Obstruction in chimney

• Downdraft from chimney tem-

perature or from negative house
pressure

• Have chimney checked if it workd

previously

• Pre-warm

chimney

Shut off exhaust devices

Open window slightly

Does the kindling wood not ignite?

Condition, amount, arrangement of
kindling and fuel

Use more, drier, well-spaced kindling
and fuel.

Does the kindling ignite, but the fuel
doesn’t?

Amount of kindling

Condition of fuel

• Use

more

kindling

Use smaller, dry wood

Does the fuel ignite, but not burn well?

Draft problem

Condition of fuel

• Use well-seasoned wood and suf-

fi cient amount

Turn exhaust fans off

Open window slightly

1. If I can’t get a good fi re going, what am I doing wrong?

2. I smell smoke in the house after we have had a fi re. What is the cause/what can I do?

Diagnostic Question

Possible Causes of Condition

Solutions

Is the chimney clean?

No: Creosote odor

Have chimney cleaned

3. I smell smoke in the house during operation. What is causing it?

Diagnostic Question

Possible Causes of Condition

Solutions

Do fi res start and burn well?

No:
• Chimney

obstruction

• Not enough kindling and/or fuel to

establish draft

Inadequate combustion air

• Air controls not open

Yes:

Competition with exhaust devices

No:
• Check & clean chimney if needed

Use adequate kindling & fuel

Open air controls

• Open

window

• Check for need for balanced air

make-up (Outside Air)

Yes:
• Do not use exhaust fans during

startup

• Check for need for balanced air

make-up (Outside Air)