10.6 Load/Unload

Be sure to issue and complete the following commands for unloading before cutting off the power
supply.

Following table shows the specification for normal load/unload cycles.

Load/unload cycle (Times)

Environment

600,000 Room

temperature

300,000

Operational temperature range


Unload is executed by the following commands :

Standby
Standby Immediate
Sleep
Hard reset


Load/Unload is also executed as one of the idle modes of the drive.

If the power supply is cut when the head is on a media, Emergency Unload is performed by routing
the back-EMF of SPM to the voice coil. In this case, Emergency Unload is performed 20,000 times
maximum. Emergency Unload should be used only when the host-system cannot perform normal
operation.