This command is available in LBA addressing only.

11.8.9 Read Verify (40h)


COMMAND CODE

0 1 0 0 0 0 0 0

REGISTER

REGISTER SETTING

NORMAL COMPLETION

DR

drive no.

no change

CY

starting cylinder

last possible

HD

starting head

last possible

SN

starting sector

start sector

SC

no. of sector to be read

00H

LBA

starting address

last address

This command is identical to a Read command except that the drive has read the data from the media, and
the DRQ bit is not set and no data is sent to the host. This allows the system to verify the integrity of the
drive. A single interrupt is generated upon completion of a command or when an error occurs.

11.8.10 Read Verify EXT (42h)

COMMAND CODE

0 1 0 0 0 0 1 0

REGISTER

REGISTER SETTING

NORMAL COMPLETION

DR

drive no.

no change

LBA

Low

Current

Previous

LBA(7:0)

LBA(31:24)

HOB=0
HOB=1

last address
last address

LBA

Mid

Current

Previous

LBA(15:8)

LBA(39:32)

HOB=0
HOB=1

last address
last address

LBA
High

Current

Previous

LBA(23:16)
LBA(47:40)

HOB=0
HOB=1

last address
last address

SC Current

Previous

sector count(7:0)

sector count(15:8)

HOB=0
HOB=1

00H
00H

FT Current

Previous

reserved
reserved

HOB=0
HOB=1

no change
no change

This command is identical to a Read EXT command except that the drive has read the data from the media,
and the DRQ bit is not set and no data is sent to the host. This allows the system to verify the integrity of
the drive. A single interrupt is generated upon completion of a command or when an error occurs.

This command is available in LBA addressing only.

Advertising
This manual is related to the following products: