Table 11.8-4 Identify Information (Continued)

WORD

DESCRIPTION

Hex.

87

Command set/feature default
15 0 (Fixed)
14 1 (Fixed)
13 1 (Fixed)
12-6 Reserved
5 1=General Purpose Logging feature set supported
4 Reserved
3 1=Media Card Pass Through Command feature set enabled
2 1=Madia serial number is valid
1 1=SMART self-test supported

6023

88

15-8 Ultra DMA transfer mode selected
7-0 Ultra DMA transfer modes supported

XX3F

89

Time required for security erase unit completion

00XX

90

Time required for Enhanced Security erase completion

0000

91

Current Advanced Power Management setting
15-8 Reserved

7-0 Current Advanced Power Management setting set by Set Features

Command

00XX

92

Master Password Revision Code

XXXX

93

Hardware reset result. The conetnts of bits 12-0 of this word shall change only
during the execution of a hardware reset.

15 0

(Fixed)

14 1 (Fixed)

13 1=device detected CBLID- above V

IH

0=device detected CBLID- below V

IL

12-8

Device 1 hardware reset result. Device 0 shall clear these bits to
zero.
Device 1 shall set these bits as follows :

12 Reserved.
11

0=Device 1 did not assert PDIAG-.
1=Device 1 asserted PDIAG-.

10-9

These bits indicate how Device 1 determined the device
number:
00=Reserved.
01=a jumper was used.
10=the CSEL signal was used.
11=some other method was used or the method is
unknown.

8 1

(Fixed)

7-0

Device 0 hardware reset result. Device 1 shall clear these bit to
zero.
Device 0 shall set these bills as follows:

7 Reserved.
6

0=Device 0 does not respond when Device 1 is selected.
1=Device 0 responds when Device 1 is selected.

5

0=Device 0 did not detect the assertion of DASP-.
1=Device 0 detected the assertion of DASP-.

4

0=Device 0 did not detect the assertion of PDIAG-.
1=Device 0 detected the assertion of PDIAG-.

3

0=Device 0 failed diagnostics.
1=Device 0 passed diagnostics.

2-1

These bits indicate how Device 0 determined the device
number:
00=Reserved.
01=a jumper was used.
10=the CSEL signa was used.
11=some other method was used or the method is
unknown.

0 1 (Fixed)

XXXX

94

Current automatic acoustic management value
15-8 Vendor’s recommended acoustic management value
7-0 Current automatic acoustic management value

0000

95-99 Reserved

0000

100-103

Maximum user LBA for 48-bit Address feature set

XXXX

104-126 Reserved

0000