background image

Conversation Between the TLV1562 and the DSP

15

Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP

7.4

Dual Interrupt Driven Mode

Using techniques similar to those described in the first two modes for
sampling/converting/sending tasks, the dual mode samples two channels at the
same time and sends out the results in series to the data port. The CSTART pin
is used to start sampling and converting.

Table 9. DSP Algorithm for Dual Interrupt Driven Mode

Wait cycles for the DSP internally (40MHz DSPCLK):

STEPS

TIMING, NOTES

APD=0

ADCSYCLK

= 7.5MHz

APD=0

ADCSYCLK

= 10MHz

APD=1

ADCSYCLK

= 10MHz

APD=1

ADCSYCLK

= 10MHz

1.

Set CS

Deselect ADC

2.

Clear CSTART

This starts sampling

3.

Wait for t

W(CSTARTL)

t

W(CSTARTL)

= 100ns

(APD=0)

t

W(CSTARTL)

= 600ns

(APD=1)

4

4

24

24

4.

Set CSTART

This starts the conversion

5.

Wait until INT goes low

Alternative: ignore the INT signal,
wait 210ns+10 ADCSYSCLK and go
to step number 7

62

48

62

48

6.

Wait the time t

D(INTL-CSL)

t

D(INTL-CSI)

= 10 ns

1

1

1

1

7.

Clear CS

Select the ADC

8.

Clear RD

Start communication

9.

Wait the time t

EN(DATAOUT)

t

EN(DATAOUT)

= 41 ns

2

2

2

2

10.

Read sample out from the data port;
reset RD signal

11.

Wait t

W(CSH)

t

W(CSH)

= 50 ns

2

2

2

2

12.

Clear RD-

Start communication

13.

Wait the time t

EN(DATAOUT)

t

EN(DATAOUT)

= 41 ns

2

2

2

2

14.

Read sample out from the data port;
reset RD signal

15.

Set CS

Deselect ADC

16.

Goto step 2 for the next samples