5 mono continuous mode – Texas Instruments TLV1562 User Manual

Page 22

Advertising
background image

Conversation Between the TLV1562 and the DSP

16

SLAA040

7.5

Mono Continuous Mode

This mode simplifies data acquisition, since there is no need to generate a signal
to sample or convert data. Instead, initializing this mode once, the ADC sends out
the data continuously and will be read by the DSP with the RD signal.

CAUTION:

In this mode, the sampling result sent out by the ADC is the
value of the sample from the last cycle. Therefore, the first
sample after initialization is trash.

Table 10. DSP Algorithm for Mono Continuous Mode

Wait cycles for the DSP internally (40MHz DSPCLK):

STEPS

TIMING, NOTES

APD=0

ADCSYCLK

= 7.5 MHz

APD=0

ADCSYCLK

= 10 MHz

APD=1

ADCSYCLK

= 10 MHz

APD=1

ADCSYCLK

= 10 MHz

0.

Initialization

N/A

N/A

Write all configuration data to the
ADC

Activate the mono continuous mode in
CR0(2;3)

N/A

N/A

1.

Set CS

Deselect ADC

N/A

N/A

2.

wait for t

(SAMPLE1)

t

(SAMPLE1)

= 100 ns

4

4

N/A

N/A

3.

Clear CS

Select ADC

N/A

N/A

4.

Clear RD

Start conversion

N/A

N/A

5.

Wait the time t

EN(DATAOUT)

t

EN(DATAOUT)

= 41 ns

2

2

N/A

N/A

6.

Read sample out from the data port;
reset RD signal

(Caution: the first result after initialization
is trash)

N/A

N/A

7.

Wait for the time t

(CONV1)

minus

step 7 and 8 to ensure 5(6) ADC-
SYSCLk

t

(CONV1)

= 5(6) ADCSYSCLK; since step

7 and 8 take at least 4 DSPSYSCLK, the
calculation are 5(6) ADCSYSCLK minus
100 ns

23

16

N/A

N/A

8.

Go to step 4 for more samples

N/A

N/A