Appendix a command set summary – Trango Broadband TrangoLink-10 User Manual

Page 30

Advertising
background image

Command Set Summary

Trango Broadband Wireless — TrangoLINK-10 User Manual Rev. E 3.0

page 26

Appendix A Command Set Summary

• OFF = Opmode “OFF,” ON = Opmode “ON”

• s = serial, e = Ethernet

• + It may not work properly through HTTP’s command console.


Command Description

OFF

ON

Remark

!+

redo the last command

s

s

?

same as “help” se

se

? <command>

same as “help” se

se

_password <new password>
<new password>

specify new password (max 15octs)

se

se

arp –bcast [<on | off>]

enables/disables the sending of periodic arp
broadcast packets to gateway

se se

baud [<9600 | 115200>]

display or set console baud rate

se

se

default = 9600 bps

bye

same as “logout” se

se

eth <link | r | w | reset>

display or set Ethernet setting

se

se

exit

same as “logout” se

se

freq

display current channel

se

se

freq <ch#> <h | v>

change current channel and polarization

se

se

freq channeltable

display channel table

se

se

freq writechannel [<ch #>
<freq>]…

build channel and write to flash
<ch #> = 1..30

se se

heater [<on temp, 0..19> <off
temp, 1..20>]

set heater parameters

se

se

help

display complete help page except “eng”

se

se

help <command>

search and display command’s help

se

se

ipconfig [<new ip> <new subnet
mask> <new gateway>]+

assign radio’s IP, subnet mask, and
gateway IP

se se

logout logout

of

console se

se

maclist macexp <30..600>

change expiration time of MAC entry in
maclist

se

se

AP’s default is 600s
SU’s default is 30s

maclist filter [<on | off>]

filter out all local Ethernet packets

se

se

default: on

maclist [<reset>]

display or reset current MAC table

se

se

msearch <sec> <ch#>
<h | v>…

Master search – RU will search for MU on
specified channel and polarization.

se

opmode [<on | off>]

set or display current Opmode

se

se

password

specify new password (max 15octs)

s

s

ping <ip address>

ping local Ethernet device

se

se

It only works for local
Ethernet devices, not
SU or any device behind
SU.

power

display default and current TX power level

se

se

default = +18 dBm

power <setism>
<min | max | dBm>

specify TX power for both band

se

se

SU’s power will be
adjusted by MU when
association

ru ipconfig <new ip> <new
subnet> <new gateway>

assign Remote ipconfig

se

ru ping

ping Remote Radio

se

ru powerleveling

power levels RU to reach Target RSSI, set
in MU

se

Advertising