6 ata activation instructions – Telstrat Argent User Manual

Page 9

Advertising
background image

Argent Terminal Adaptor - User Guide

Version 1.1

Telstra Corporation Limited

Page 9/29

ACN 051 775 556

Only the decimal point on the Seven Segment Display is illuminated when the
configuration has been downloaded successfully by the Argent NMS, and the ATA is
functioning correctly with connected EFTPOS terminals responding normally. No other
codes will be displayed on the Seven Segment Display in this mode and the unit can be
assumed to be correctly configured and operational.

If the ATA is commissioned before it is connected to an EFTPOS machine then it will
display a flashing 3 until the EFTPOS machine is connected.

3.6 ATA Activation Instructions

Telstra should supply the following information after the OnRamp® 2 D-Channel service
has been installed and tested.

Argent EFTPOS service FNN:

FNN =

FxxxxxxxxxxY (Argent Dedicated Service)
FxxxxxxxxxxT (Argent Test Service)

where xxxxxxxxxx is the 10 digit number of the OnRamp® 2 service.

TEI number (S-Bus D channel address for the ATA. Factory default OnRamp® 2 is

63, Microlink® requires 1. See section 3.6.6 )

Whether this is a migration from Transend to Argent service.

The steps following can then be followed:

3.6.1 Prepare position

The ATA can be installed either horizontally or vertically. Make sure that it is close to
the OnRamp® 2 NT1 (2 metres) and a 240V outlet and within reach of the EFTPOS
terminal. Avoid placing the unit in direct sunlight or near hot surfaces.

3.6.2 Connect ATA to NT1

Connect the ATA ISDN Port to the OnRamp® 2 NT1 S-Bus using only the supplied
cable. The end marked “Terminal” is keyed to fit into the ATA’s ISDN port. The end
marked “Network” is plugged into the NT1.

3.6.3 Connect the EFTPOS terminal to ATA

Connect the cord from the EFTPOS terminal into the EFTPOS 611 connector on the ATA
back panel. In some cases it may be possible to bypass an existing EFTPOS modem and
go directly into the V.24 modem. Telstra will be able to advise if this is possible, and set
up the ATA from the Management system to accommodate this connection.