A Trimble Standard Interface Protocol

74 Trimble ThunderBolt E GPS Disciplined Clock User Guide

Command Packet 8E-A9 Data Format

Command Packet 0x8E-AB: Request Primary Timing Packet

Use command packet 0x8E-AB to request the Primary Timing packet 0x8F-AB. By
default, the receiver automatically sends packet 0x8F-AB once per second so it is not
necessary to request it. To receive 0x8F-AB information by request only, use packet
0x8E-A5 to disable the automatic output.

The Request Type item determines how the receiver will reply to this command:

Command Packet 0x8E-AB Data Format

Byte

Item

Type

Value

Description

0

Subcode

UINT8

0xA9

1

Self-Survey Enable UINT8

0

1

Disabled

Enabled

2

Position Save Flag

UINT8

0

1

Don't save position

Save self-surveyed position at the end of
the survey

3-6

Self-Survey Length UINT32 see above Number of fixes

7-10

Reserved

UINT32 0

0

Type

Description

0

The most current primary timing values will be sent in packet 0x8F-AB immediately.

1

The response is not sent immediately. Instead packet 0x8F-AB is sent after the next
PPS output. This is the same time that the packet would be automatically sent if
enabled.

2

Same as type 1 except that both 0x8F-AB and 0x8F-AC are sent after the next PPS
output.

Byte

Item

Type

Value

Meaning

0

Subcode

UINT8

0xAB

1

Request type

UINT8

0

Send 0x8F-AB immediately

1

Send 0x8F-AB on-time next second

2

Send 0x8F-AB and 0x8F-AC on-time next
second

Advertising