Trimble Outdoors THUNDERBOLT 64057-00-ENG User Manual

Page 77

Advertising
background image

Trimble ThunderBolt E GPS Disciplined Clock User Guide

75

Trimble Standard Interface Protocol

A

Command Packet 0x8E-AC: Request Supplementary Timing Packet

Use command packet 8E-AC to request the Supplemental Timing packet 0x8F-AC. By
default, the receiver automatically sends packet 0x8F-AC once per second so it is not
necessary to request it. To receive 0x8F-AC information by request only, use packed
0x8E-A5 to disable the automatic output.

The Request Type item determines how the receiver will reply to this command:

Command Packet 0x8E-AC Data Format

Report Packet 0x8F-15 Current Datum Values

This packet contains the values for the datum currently in use and is sent in response
to packet 8E-15. If a built-in datum is being used, both the datum index and the five
double-precision values for that index are returned. If the receiver is operating on a
custom user-entered datum, the datum index is set to -1 and the five values are
displayed. These five values describe an ellipsoid to convert ECEF XYZ coordinate
system into LLA.

Type

Description

0

The most current primary timing values will be sent in packet 0x8F-AC immediately.

1

The response is not sent immediately. Instead packet 0x8F-AC is sent after the next
PPS output. This is the same time that the packet would be automatically sent if
enabled.

2

Same as type 1 except that both 0x8F-AB and 0x8F-AC are sent after the next PPS
output.

Byte

Item

Type

Value

Meaning

0

Subcode

UINT8

0xAC

1

Request type

UINT8

0

Send 0x8F-AC immediately

1

Send 0x8F-AC on-time next second

2

Send 0x8F-AB and 0x8F-AC on-time next
second

Byte

Type

Value

Description

0

Super Packet ID

14

1-2

Datum index (-1 for custom)

Datum Index

3-10

DOUBLE

DX

meters

11-18

DOUBLE

DY

meters

19-26

DOUBLE

DZ

meters

27-34

DOUBLE

A-axis

meters

35-42

DOUBLE

Eccentricity squared

none

Advertising