Trimble Outdoors THUNDERBOLT 64057-00-ENG User Manual
Page 84
A Trimble Standard Interface Protocol
82 Trimble ThunderBolt E GPS Disciplined Clock User Guide
5
Not used
6
Disciplining Disabled
3
Self-Survey Progress
UINT8
0-100%
4-7
Holdover Duration
UINT32
0
Seconds
8-9
Critical Alarms
UINT16
Bit field
Bit 4: DAC at rail
10-11
Minor Alarms
UINT16
Bit field
Bit 0: DAC near rail
Bit 1: Antenna open
Bit 2: Antenna shorted
Bit 3: Not tracking satellites
Bit 4: Not disciplining oscillator
Bit 5: Survey-in progress
Bit 6: No stored position
Bit 7: Leap second pending
Bit 8: In test mode
Bit 9: Position is questionable
Bit 10: Not used
Bit 11: Almanac not complete
Bit 12: PPS not generated
12
GPS Decoding Status
UINT8
0x00
Doing fixes
0x01
Don't have GPS time
0x03
PDOP is too high
0x08
No usable sats
0x09
Only 1 usable sat
0x0A
Only 2 usable sats
0x0B
Only 3 usable sats
0x0C
The chosen sat is unusable
0x10
TRAIM rejected the fix
13
Disciplining Activity
UINT8
0
Phase locking
1
Oscillator warm-up
2
Frequency locking
3
Placing PPS
4
Initializing loop filter
5
Compensating OCXO (holdover)
6
Inactive
7
Not used
8
Recovery mode
9
Calibration/control voltage
14
Spare Status 1
UINT8
0
15
Spare Status 2
UINT8
0
16-19
PPS Offset
Single
ns
20-23
Clock Offset
Single
ppb
24-27
DAC Value
UINT32
Byte
Item
Type
Value
Description